  • Step motors specifically designed for high-performance applications in vacuum, cryogenic, high temperature, and radiation environments.
  • ,
  • Vacuum Capability: Effective operation in environments reaching up to 10-7Pa.
  • ,
  • Operating Temperature Range: From an impressive -196°C to a maximum of 200°C.
  • ,
  • Radiation Resistance: Robust performance withstanding radiation levels of up to 106Gy.
  • ,
  • Base Width Options: Available in a variety of widths: 30/40/60/80/135/170mm to fit diverse applications.
  • ,
  • Load Capacity: Designed to support up to 150Kg in horizontal configurations and 100Kg in vertical configurations.
  • ,
  • Precision Repeatability: Exceptional repeatability of ±0.01mm, ensuring consistent performance.
  • ,
,

As a leading factory and suppliers in China, we provide high-quality stepper motors that meet stringent industry standards for durability and reliability in complex environments.

,
,

    Ordering Information
    KLS Series Ordering Code
    1 Product Series

    KLS series linear motion stage

    2 Base Width (mm)

    30 = 30mm | 40 = 40mm | 60 = 60mm

    80 = 80mm | 140 = 135mm | 170 = 170mm

    3 Stroke Length (mm)

    50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 950, 1000, 1050, 1100, 1150, 1200, 1250, 1300, 1350, 1400, 1450, 1500

    * Please refer to the specification tables for the available stroke length.

    4 Screw Lead (mm)

    2, 4, 5, 10, 16, 20mm

    * Please refer to the specification tables for the available screw lead.

    5 Motor Mounting

    ISC: In-line (with coupling)

    PR: Parallel on right side (with high precision gear, ratio 1:1)

    PL: Parallel on left side (with high precision gear, ratio 1:1)

    PB: Parallel below the linear motion stage (with high precision gear, ratio 1:1)

    Motor Mounting Configurations
    6 Environmental Temperature Ratings
    Environmental Temperature Rating Code Temperature Range (℃) Vacuum Class (Pa, optional) Radiation Resistance (Gy, optional)
    RHT -20 ~ +200 10-3 106
    SHT -20 ~ +200 10-3/10-5/10-7 -
    HT -20 ~ +150 10-3/10-5/10-7 -
    NTL1 -40 ~ +85 10-3/10-5 -
    NTL2 -40 ~ +100 - -
    NTL3 -65 ~ +125 10-3 -
    NTL4 -80 ~ +40 10-3 -
    NTL5 -55 ~ +150 - -
    7 Vacuum Class

    Blank: Non-vacuum

    V3: Low pressure or vacuum to 10-3Pa

    V5: Vacuum to 10-5Pa

    V7: Vacuum to 10-7Pa

    8 Radiation Resistance

    Blank: No radiation resistance

    RH: Radiation resistance (total dose 106Gy)

    9 Designator of Mounted Motor

    KH42: KH series 42mm stepper motor

    KVM57: KVM series 57mm stepper motor

    KECM400: KECM series 400W servo motor

    KSSM750: KSSM series 750W servo motor

    PB60L2: PB60 2-stage reducer (please specify the reducer stage, e.g. L1 or L2)

    Description

    Core Perspective: Balancing "low-temperature sample viability" with "contamination prevention" in automated workflows

    The core dilemma of automated genetic sampling equipment is that sample viability demands a consistently cryogenic environment (-196°C liquid nitrogen), while mechanical transmission systems conventionally freeze and fail at such temperatures due to lubricant solidification. The KLS Series High-Low Temperature Linear Module resolves this contradiction. This high-low temperature linear module is specifically optimized for low-temperature automation in the biomedical industry, focusing on startup torque characteristics. When the ambient temperature plummets to min -196°C, standard motors suffer step-loss as the coercivity of their magnets degrades. In contrast, this high-low temperature linear module employs samarium-cobalt (SmCo) cryogenic-grade magnets, ensuring rated torque output even at liquid nitrogen temperatures.

    During the lysis step of nucleic acid extraction, the equipment may rapidly heat to max +200°C to inactivate proteases. The housing of this high-low temperature linear module undergoes special heat treatment to withstand repeated thermal stress without distortion. For sterile sampling requirements, the surface of this high-low temperature linear module is coated with a material resistant to ethanol and vaporized hydrogen peroxide (VHP), with a seamless, crevice-free design facilitating cleaning validation. Operating under a vacuum degree of 10^-7Pa, this high-low temperature linear module suits next-generation fully enclosed sterile sampling systems, effectively preventing cross-contamination. Remarkably, the KLS Series High-Low Temperature Linear Module withstands radiation intensity of 10^6Gy, meaning it will not become a source of radiation-induced degradation when used on production lines for radiation-sterilized vaccines.

    Regarding mechanical selection, the miniature body width of 30mm high-low temperature linear module can be directly embedded into the sampling platform of a microfluidic chip. Its repeatability of ±0.01mm ensures precise alignment between the pipette tip and the microwell. Meanwhile, the wide-body 135mm width version, with a maximum vertical load capacity of 100kg, can carry an entire deep-well plate stacker. In an automated library preparation workstation for next-generation sequencing (NGS), multiple high-low temperature linear modules work in concert, performing all actions from magnetic bead mixing and washing to elution. The key here is that after repeated operation at min -196°C, the straightness of the high-low temperature linear module does not degrade due to microscopic ice crystal formation on rail surfaces. The KLS Series High-Low Temperature Linear Module incorporates precision scrapers and anti-condensation airflow designs, maintaining ±0.01mm repeatability even under extreme humidity swings. For high-throughput qPCR systems used in pathogen detection, this high-low temperature linear module rapidly shuttles sample plates between different temperature zones, compressing overall reaction time. In summary, the KLS Series High-Low Temperature Linear Module is not merely a transmission component; it is a core enabler of sample integrity and high-throughput automation in biomedicine.

    KLS Linear Module Application
    Frequently Asked Questions (FAQ)
    What is the operating temperature range of the KLS Series Linear Module?
    The KLS Series is engineered to withstand extreme temperatures, operating reliably from cryogenic environments as low as -196°C up to high-temperature conditions of +200°C.
    How does the module maintain performance in cryogenic liquid nitrogen environments?
    Unlike standard motors that suffer step-loss when magnets degrade at low temperatures, the KLS Series utilizes samarium-cobalt (SmCo) cryogenic-grade magnets to guarantee rated torque output even at -196°C.
    Is the KLS Series suitable for sterile and vacuum environments?
    Yes, it supports vacuum operations up to 10-7Pa. The module features a seamless, crevice-free design with a surface coating resistant to ethanol and vaporized hydrogen peroxide (VHP), making it ideal for sterile cleaning validation.
    What is the positioning repeatability of the KLS Linear Module?
    The module achieves a high repeatability of ±0.01mm. This ensures precise alignment for delicate procedures such as microfluidic pipetting, even under extreme humidity and temperature transitions.
    Can this module be used in high-radiation environments?
    Yes, the KLS Series can withstand radiation intensities up to 106Gy, ensuring it does not degrade when deployed on automated production lines for radiation-sterilized vaccines.