Leave Your Message
High-Low Temperature Linear Module for Biomedical Use | China Suppliers & Factory for Vacuum and Cryogenic Applications
Hot Products
Products Categories
Featured Products

High-Low Temperature Linear Module for Biomedical Use | China Suppliers & Factory for Vacuum and Cryogenic Applications

Discover high-performance stepper motors designed for a range of demanding applications, including vacuum, cryogenic, high temperature, and radiation environments. Our motors are engineered to operate in extreme conditions, making them perfect for various industrial settings, Key Features:, - **Vacuum Compatibility**: Operates effectively in vacuum conditions as low as 10-7Pa, - **Wide Operating Temperature Range**: Functional at temperatures from -196°C to 200°C, ensuring reliability in both cryogenic and high-temperature applications, - **Radiation Resistance**: Capable of withstanding radiation levels up to 106Gy, ideal for applications in radiation-intensive environments, - **Customizable Base Widths**: Available in various sizes including 30mm, 40mm, 60mm, 80mm, 135mm, and 170mm, allowing for tailored solutions to fit your specific needs, - **Robust Load Capacity**: Supports a maximum load capacity of 150Kg horizontally and 100Kg vertically, providing stability and strength in your operations, - **Precision Repeatability**: Features a repeatability of ±0.01mm, ensuring accurate positioning for your critical tasks, As a leading manufacturer and supplier in China, our factory specializes in delivering high-quality stepper motors that meet the rigorous demands of various industries. Trust our expertise to provide you with the reliable performance and durability your applications require

    Ordering Information

    KLS
    ① Product series

    KLS series linear motion stage

    ② Base width(mm)

    30 = 30mm

    40 = 40mm

    60 = 60mm

    80 = 80mm

    140 = 135mm

    170 = 170mm

    ③ Stroke length(mm)

    50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 950, 1000, 1050, 1100, 1150, 1200, 1250, 1300, 1350, 1400, 1450, 1500

    Please refer to the specification tables for the available stroke length.

    ④ Screw lead(mm)

    2, 4, 5, 10, 16, 20mm

    Please refer to the specification tables for the available screw lead.

    ⑤ Motor mounting

    ISC: in-line (with coupling)

    PR: parallel on right side (with high precision gear, ratio 1:1)

    PL: parallel on left side (with high precision gear, ratio 1:1)

    PB: parallel below the linear motion stage (with high precision gear, ratio 1:1)

    12
    ⑥ Environmental temperature ratings
    Environmental temperature rating code Temperature range (℃) Vacuum class (Pa, optional) Radiation resistance (Gy, optional)
    RHT -20~+200 10-3 106
    SHT -20~+200 10-3/10-5/10-7 -
    HT -20~+150 10-3/10-5/10-7 -
    NTL1 -40~+85 10-3/10-5 -
    NTL2 -40~+100 - -
    NTL3 -65~+125 10-3 -
    NTL4 -80~+40 10-3 -
    NTL5 -55~+150 - -
    ⑦ Vacuum class

    Blank = Non-vacuum

    V3 = Low pressure or vacuum to 10-3Pa

    V5 = Vacuum to 10-5Pa

    V7 = Vacuum to 10-7Pa

    ⑧ Radiation resistance

    Blank = No radiation resistance

    RH = Radiation resistance (total dose 106Gy)

    ⑨ Designator of mounted motor

    e.g.

    KH42 = KH series 42mm stepper motor

    KVM57 = KVM series 57mm stepper motor

    KECM400 = KECM series 400W servo motor

    KSSM750 = KSSM series 750W servo motor

    PB60L2 = PB60 2-stage reducer (please specify the reducer stage, e.g. L1 or L2)

    Description

    Core Perspective: Balancing "low-temperature sample viability" with "contamination prevention" in automated workflows

    The core dilemma of automated genetic sampling equipment is that sample viability demands a consistently cryogenic environment (-196°C liquid nitrogen), while mechanical transmission systems conventionally freeze and fail at such temperatures due to lubricant solidification. The KLS Series High-Low Temperature Linear Module resolves this contradiction. This high-low temperature linear module is specifically optimized for low-temperature automation in the biomedical industry, focusing on startup torque characteristics. When the ambient temperature plummets to min -196°C, standard motors suffer step-loss as the coercivity of their magnets degrades. In contrast, this high-low temperature linear module employs samarium-cobalt (SmCo) cryogenic-grade magnets, ensuring rated torque output even at liquid nitrogen temperatures.

    During the lysis step of nucleic acid extraction, the equipment may rapidly heat to max +200°C to inactivate proteases. The housing of this high-low temperature linear module undergoes special heat treatment to withstand repeated thermal stress without distortion. For sterile sampling requirements, the surface of this high-low temperature linear module is coated with a material resistant to ethanol and vaporized hydrogen peroxide (VHP), with a seamless, crevice-free design facilitating cleaning validation. Operating under a vacuum degree of 10^-7Pa, this high-low temperature linear module suits next-generation fully enclosed sterile sampling systems, effectively preventing cross-contamination. Remarkably, the KLS Series High-Low Temperature Linear Module withstands radiation intensity of 10^6Gy, meaning it will not become a source of radiation-induced degradation when used on production lines for radiation-sterilized vaccines.

    Regarding mechanical selection, the miniature body width of 30mm high-low temperature linear module can be directly embedded into the sampling platform of a microfluidic chip. Its repeatability of ±0.01mm ensures precise alignment between the pipette tip and the microwell. Meanwhile, the wide-body 135mm width version, with a maximum vertical load capacity of 100kg, can carry an entire deep-well plate stacker. In an automated library preparation workstation for next-generation sequencing (NGS), multiple high-low temperature linear modules work in concert, performing all actions from magnetic bead mixing and washing to elution. The key here is that after repeated operation at min -196°C, the straightness of the high-low temperature linear module does not degrade due to microscopic ice crystal formation on rail surfaces. The KLS Series High-Low Temperature Linear Module incorporates precision scrapers and anti-condensation airflow designs, maintaining ±0.01mm repeatability even under extreme humidity swings. For high-throughput qPCR systems used in pathogen detection, this high-low temperature linear module rapidly shuttles sample plates between different temperature zones, compressing overall reaction time. In summary, the KLS Series High-Low Temperature Linear Module is not merely a transmission component; it is a core enabler of sample integrity and high-throughput automation in biomedicine.

    3-3

    Frequently Asked Questions

    What is the minimum and maximum operating temperature for the KLS Series?
    Depending on the environmental temperature rating selected, the KLS Series can operate in extreme conditions ranging from as low as -80°C (NTL4 rating) up to +200°C (RHT and SHT ratings). It is designed to maintain performance even down to liquid nitrogen temperatures (-196°C) using cryogenic-grade magnets.
    Can this linear module operate in high-vacuum environments?
    Yes, the KLS Series offers configurations compatible with high-vacuum environments. You can select vacuum class options ranging from V3 (10-3Pa), V5 (10-5Pa), up to V7 (10-7Pa) for fully enclosed sterile sampling applications.
    What is the positioning repeatability and load capacity of the KLS stage?
    The KLS Series delivers a high repeatability of ±0.01mm. The load capacity varies by base width, with the wide-body 135mm version supporting a maximum vertical load capacity of up to 100kg.
    How does the stage prevent ice crystal formation and condensation at low temperatures?
    To combat microscopic ice crystal formation and condensation issues on the rail surfaces under extreme temperature and humidity changes, the module integrates precision scrapers and specialized anti-condensation airflow designs.
    Is the KLS linear stage resistant to sterilization chemicals and radiation?
    Yes, the surface is coated with materials resistant to ethanol and vaporized hydrogen peroxide (VHP) for cleanroom validation. Additionally, modules configured with the RH option can withstand radiation intensities up to 106Gy, making them suitable for sterile production lines.

    Leave Your Message